Cook® Zenith

  • Zenith Flex®

    Suprarenal Fixation with Anchoring Barbs

    Established suprarenal design with anchoring barbs is the benchmark for stability and graft-to-vessel attachment.

    Flex Design

    Increased gap length allows aortic section to conform to a tighter radius resulting in a 40-68% decrease in kink radius.

    Radiopaque Band

    Identifies precise location of sheath’s distal tip.

    Flexor® Introducer Sheath

    Kink-resistant technology with low-friction hydrophilic coating.

    AQ® Hydrophilic Coating

    Dramatically reduces friction to enhance deliverability, while Flexor’s large, low-friction PTFE-coated lumen facilitates device delivery.

    Captor® Haemostatic Valve

    Unique design inhibits blood reflux.

  • Zenith Flex®

    Suprarenal Fixation with Anchoring Barbs

    Established suprarenal design with anchoring barbs is the benchmark for stability and graft-to-vessel attachment.

     

    Flex Design

    Increased gap length allows aortic section to conform to a tighter radius resulting in a 40-68% decrease in kink radius.

     

    Radiopaque Band

    Identifies precise location of sheath's distal tip.

     

    Flexor® Introducer Sheath

    Kink-resistant technology with low-friction hydrophilic coating.

     

    AQ® Hydrophilic Coating

    Dramatically reduces friction to enhance deliverability, while Flexor's large, low-friction PTFE-coated lumen facilitates device delivery.

     

    Captor® Haemostatic Valve

    Unique design inhibits blood reflux.

  • Zenith Thoracic

    About the Zenith TX2®

    Flexor Introducer Sheath

    Hydrophilic coating for smooth access.

    Inner Metal Cannula

    Offers column strength and over-the-wire trackability.

    Radiopaque Band

    Identifies precise location of sheath’s distal tip.

    Circumferential Barbs

    The only device with barbs on both the proximal and distal end of the device.

    Migration Prevention

    Circumferential barbs with radial fixation enable the graft to self-adjust to patient’s dynamic aortic movement.

    Sound Lineage

    TX2 uses the same durable construction as the Zenith platform for graft-to-vessel sealing.

    About the Zenith® Dissection

    The TX2 graft, combined with bare Z-stents down the true lumen, represents a more complete and holistic treatment for dissection.

    Treating aortic AND branch vessel compromise (malperfusion): Instead of just deploying a sealing stent graft across the intimal entry tear, the combination of the two devices provides sealing, reinforcement, and branch vessel reperfusion. Important intercostal and mesenteric branches are protected.

    Customised treatment: A variety of diameters and lengths of (TX2) sealing grafts provide for adequate closure of the entry tear while not covering any more of the aorta and visceral branches than necessary.

    Precision Delivery: Signature Zenith trigger-wire control during deployment for both the TX2 Proximal Component and the bare Dissection Z-stents provides reliable, accurate device deployment in high thoracic aortic flow.

  • Zenith® Branch

    More Options

    For patients with aortoiliac or iliac aneurysms and insufficient sealing sites within the common iliac artery.

    Unique Sidebranch

    Allows blood flow to internal iliac, reducing the potential for ischemic sequelae.

    H&L-B One-Shot Introduction System

    Allows adjustment of the graft position before complete deployment.

    Pre-Loaded Catheter

    Facilitates internal iliac cannulation.

    Independent Z-stent Design

    Provides graft flexibility and columnar strength.

    Woven Polyester

    Strong, lightweight, shrink-resistant material has been used historically to treat AAAs.

  • Zenith® Fenestrated

    Custom Fenestrations

    Allow placement above the renal arteries without interrupting renal blood flow.

    Diameter Reducing Ties

    Decrease graft diameter to facilitate visceral vessel cannulation.

    Precise Placement

    Each fenestration is equipped with radiopaque markers.

    Wide Patient Range

    Treatment options for patients with proximal infrarenal necks ranging from 4 mm to 15 mm in length and from 19 mm to 31 mm in diameter.

    Custom Tailored

    Each graft accommodates up to three fenestrations to fit patient’s unique vasculature.

    Radiopaque Markers

    Allow precise placement of each fenestration.