• Cook® Check-Flo Performer® Introducer Sets

    Used to introduce balloon, electrode, closed or nontapered-end and other catheters.

    • The sidearm fitting allows flushing around the catheter while it is positioned around the sheath.
    • The side-connection line can be used as a second infusion line

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Check-Flo Performer® Introducer Sets – Micropuncture® Access

    Used to introduce balloon, closed or nontapered-end catheters and other devices.

    • Sets feature Micropuncture access which includes a .018 inch platinum-tipped nitinol or stainless steel wire guide and a 21 gauge access needle.
    • The sidearm fitting allows flushing around the catheter while it is positioned inside the sheath.
    • The side-connection line can be used as a second infusion line.

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Check-Flo Performer® Introducer Sets – Micropuncture® Radial Artery Access

    Used to introduce balloon, diagnostic and guiding catheters or devices.

    • Sets feature Micropuncture access which includes a .018 inch platinum-tipped nitinol wire guide and a 21 gauge access needle
    • The introducer sheath dilator incorporates a van Andel taper to facilitate placement into the vessel
    • The sidearm fitting allows flushing around the catheter while it is positioned inside the sheath
    • The side-connection line can be used as a second infusion line.

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Check-Flo Performer® Introducers – High Volume Infusion Design

    Used for the introduction of catheters, balloons and other devices.

    • The large sidearm fitting is specifically designed for high-volume fluid administration
    • Colour-coded plastic clamps can be used to identify access site location

    Supplied sterile in peel-open packages. Intended for one time use

  • Cook® Check-Flo Performer® Introducers – Mullins Design

    Used to introduce balloon electrode, closed or nontapered-end catheters and other devices

    • Sheath construction features FEP polymer which increases flexibility and maintains curve retention during procedural use
    • Radiopaque tip identifies precise location of sheath’s distal tip for positioning accuracy
    • The sidearm fitting allows flushing around the catheter while it is positioned inside the sheath
    • The side-connection line can be used as a second infusion line.

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Check-Flo Performer® Introducers – Myocardial Biopsy Modification

    Used to introduce balloon,electrode, closed or nontapered-end catheters and other devices.

    • Radiopaque tip identifies precise location of sheath’s distal tip for positioning accuracy
    • The sidearm fitting allows flushing around the catheter while it is positioned inside the sheath
    • The side-connection line can be used as a second infusion line

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Check-Flo® Accessory Adapter

    The Check-Flo adapter can be connected to the proximal end of any Luer lock sheath.

    • The self-adjusting seal in the adapter prevents blood reflux and air aspiration during the introduction of catheters or instruments
    • The side-connection line can be used as a second infusion line.

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Check-Flo® Assembly

    The Check-Flo Assembly can be connected to the proximal end of any Luer lock sheath.

    • The self-adjusting seal in the adapter prevents blood reflux and air aspiration during the introduction of catheters and instruments

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Check-Flo® Introducer Sets – Large Valve Assembly

    Used to introduce balloon, closed or nontapered-end catheters and other devices.

    • The sidearm fitting allows flushing around the catheter while it is positioned inside the sheath
    • The side-connection line can be used as a second infusion line

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Check-Flo® Introducers – Hausdorf-Lock Atrial

    Used to introduce balloon, electrode, closed or nontapered-end catheters and other devices.

    • Sheath construction features FER polymer which increases flexibility and maintains curve retention during procedural use.
    • Radiopaque tip identifies precise location of sheath’s distal tip for positioning accuracy

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Flexor® Check Flo® Introducer Sets – Micropuncture® Radial Artery Access

    Used to introduce balloon, diagnostic and guiding catheters or other devices.

    • Uniquely fabricated sheath design provides maximum flexibility without kinking or compression
    • Initial access is gained using a 21 gauge entry needle
    • The 0.018 inch nitinol wire guide with platinum tip is advanced through the needle and the needle removed.
    • The introducer sheath dilator incorporates a van Andel taper to facilitate placement into the vessel.
    • The Check-Flo haemostasis valve accepts a broad range of sizes while preventing blood reflux and air aspiration
    • The outer surface of the introducer and the distal tip of the inner dilator are coated with AQ® hydrophilic coating.
    • The coating, when wet, provides an extremely low coefficient of friction, easing introduction into the vascular system.

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Flexor® Check Flo® Introducers – Ansel Modification

    Used to introduce balloon, closed and nontapered-end catheters or other devices.

    • Uniquely fabricated sheath design provides maximum flexibility without kinking or compression
    • .018 and .038 inch wire compatible dilators included
    • Preformed curves combined with soft distal tip allow atraumatic engagement of target vessels
    • Short dilator tip enhances trackability and facilitates positioning of introducer assembly in tight spaces
    • Radiopaque band, incorporated with sheath material, identifies precise location of sheath’s distal tip for positioning accuracy
    • The Check-Flo haemostasis valve accepts a broad range of sizes while preventing blood reflux and air aspiration
    • AQ® hydrophilic coating on both sheath and dilator provide an extremely lubricious surface, easing introduction.

    Supplied sterile in peel-open packages. Intended for one-time use.