• Cook® Check-Flo Performer® Introducer Sets

    Used to introduce balloon, electrode, closed or nontapered-end and other catheters.

    • The sidearm fitting allows flushing around the catheter while it is positioned around the sheath.
    • The side-connection line can be used as a second infusion line

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Check-Flo Performer® Introducer Sets – Micropuncture® Access

    Used to introduce balloon, closed or nontapered-end catheters and other devices.

    • Sets feature Micropuncture access which includes a .018 inch platinum-tipped nitinol or stainless steel wire guide and a 21 gauge access needle.
    • The sidearm fitting allows flushing around the catheter while it is positioned inside the sheath.
    • The side-connection line can be used as a second infusion line.

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Check-Flo Performer® Introducer Sets – Micropuncture® Radial Artery Access

    Used to introduce balloon, diagnostic and guiding catheters or devices.

    • Sets feature Micropuncture access which includes a .018 inch platinum-tipped nitinol wire guide and a 21 gauge access needle
    • The introducer sheath dilator incorporates a van Andel taper to facilitate placement into the vessel
    • The sidearm fitting allows flushing around the catheter while it is positioned inside the sheath
    • The side-connection line can be used as a second infusion line.

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Check-Flo Performer® Introducers – High Volume Infusion Design

    Used for the introduction of catheters, balloons and other devices.

    • The large sidearm fitting is specifically designed for high-volume fluid administration
    • Colour-coded plastic clamps can be used to identify access site location

    Supplied sterile in peel-open packages. Intended for one time use

  • Cook® Check-Flo Performer® Introducers – Mullins Design

    Used to introduce balloon electrode, closed or nontapered-end catheters and other devices

    • Sheath construction features FEP polymer which increases flexibility and maintains curve retention during procedural use
    • Radiopaque tip identifies precise location of sheath’s distal tip for positioning accuracy
    • The sidearm fitting allows flushing around the catheter while it is positioned inside the sheath
    • The side-connection line can be used as a second infusion line.

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Check-Flo Performer® Introducers – Myocardial Biopsy Modification

    Used to introduce balloon,electrode, closed or nontapered-end catheters and other devices.

    • Radiopaque tip identifies precise location of sheath’s distal tip for positioning accuracy
    • The sidearm fitting allows flushing around the catheter while it is positioned inside the sheath
    • The side-connection line can be used as a second infusion line

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Check-Flo® Accessory Adapter

    The Check-Flo adapter can be connected to the proximal end of any Luer lock sheath.

    • The self-adjusting seal in the adapter prevents blood reflux and air aspiration during the introduction of catheters or instruments
    • The side-connection line can be used as a second infusion line.

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Check-Flo® Assembly

    The Check-Flo Assembly can be connected to the proximal end of any Luer lock sheath.

    • The self-adjusting seal in the adapter prevents blood reflux and air aspiration during the introduction of catheters and instruments

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Check-Flo® Introducer Sets – Large Valve Assembly

    Used to introduce balloon, closed or nontapered-end catheters and other devices.

    • The sidearm fitting allows flushing around the catheter while it is positioned inside the sheath
    • The side-connection line can be used as a second infusion line

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Check-Flo® Introducers – Hausdorf-Lock Atrial

    Used to introduce balloon, electrode, closed or nontapered-end catheters and other devices.

    • Sheath construction features FER polymer which increases flexibility and maintains curve retention during procedural use.
    • Radiopaque tip identifies precise location of sheath’s distal tip for positioning accuracy

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Flexor® Check Flo® Introducer Sets – Micropuncture® Radial Artery Access

    Used to introduce balloon, diagnostic and guiding catheters or other devices.

    • Uniquely fabricated sheath design provides maximum flexibility without kinking or compression
    • Initial access is gained using a 21 gauge entry needle
    • The 0.018 inch nitinol wire guide with platinum tip is advanced through the needle and the needle removed.
    • The introducer sheath dilator incorporates a van Andel taper to facilitate placement into the vessel.
    • The Check-Flo haemostasis valve accepts a broad range of sizes while preventing blood reflux and air aspiration
    • The outer surface of the introducer and the distal tip of the inner dilator are coated with AQ® hydrophilic coating.
    • The coating, when wet, provides an extremely low coefficient of friction, easing introduction into the vascular system.

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Flexor® Check Flo® Introducers – Ansel Modification

    Used to introduce balloon, closed and nontapered-end catheters or other devices.

    • Uniquely fabricated sheath design provides maximum flexibility without kinking or compression
    • .018 and .038 inch wire compatible dilators included
    • Preformed curves combined with soft distal tip allow atraumatic engagement of target vessels
    • Short dilator tip enhances trackability and facilitates positioning of introducer assembly in tight spaces
    • Radiopaque band, incorporated with sheath material, identifies precise location of sheath’s distal tip for positioning accuracy
    • The Check-Flo haemostasis valve accepts a broad range of sizes while preventing blood reflux and air aspiration
    • AQ® hydrophilic coating on both sheath and dilator provide an extremely lubricious surface, easing introduction.

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Flexor® Check Flo® Introducers – Balkin Up & Over® Contralateral Design

    Used for contralateral access to the iliac artery for interventional procedures after initial wire guide positioning has been established. NOTE: Use of a heavy-duty wire guide is recommended.

    • Uniquely fabricated sheath design provides maximum flexibility without kinking or compression
    • Sheath and dilator configuration facilitates positioning over bifurcation to opposite iliac artery
    • Radiopaque band incorporated within sheath material identifies precise location of sheath’s distal tip for positioning accuracy.
    • The Check-Flo valve prevents blood reflux and air aspiration during catheter manipulations. Optic-Loc® dilator hub secures dilator to introducer valve assembly to prevent dilator movement during insertion

    Supplied sterile in peel-open packages. Intended for one-time use only.

  • Cook® Flexor® Check Flo® Introducers – Large Valve Assembly

    Used to introduce balloon, closed and nontapered-end catheters or other devices.

    • Uniquely fabricated sheath design provides maximum flexibility without kinking or compression
    • Radiopaque band, incorporated within sheath material, identifies precise location of sheath’s distal tip for positioning accuracy
    • The Check-Flo haemostasis valve accepts a broad range of sizes while preventing blood reflux and air aspiration.

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Flexor® Check Flo® Introducers – Raabe Modification

    Used to introduce balloon, closed and nontapered-end catheters or other devices.

    • Uniquely fabricated sheath design provides maximum flexibility without kinking or compression
    • Short dilator tip enhances trackability and facilitates positioning of introducer assembly in tight spaces
    • Radiopaque band, incorporated within sheath material, identifies precise location of sheath’s distal tip
    • The Check-Flo haemostasis valve accepts a broad range of sizes while preventing blood reflux and air aspiration

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Flexor® Check Flo® Introducers – Small Valve Assembly

    Used to introduce balloon, closed, and nontapered-end catheters or other devices.

    • Uniquely fabricated sheath design provides maximum flexibility without kinking or compression
    • Radiopaque band, incorporated within sheath material, identifies precise location of sheath’s distal tip for positioning accuracy
    • The Check-Flo haemostasis valve accepts a broad range of sizes while preventing blood reflux and air aspiration.

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Flexor® Tuohy-Borst Sidearm Introducer – Shuttle Select®

    Patented Flexor sheath design provides maximum flexibility without kinking or compression.

    • Stiffened proximal shaft design enables superior pushability and support for devices
    • Atraumatic tip with unique transition zone reduces vessel trauma
    • AQ® hydrophilic coating on the distal 50cm dramatically reduces friction during introduction and manipulation
    • Distal radiopaque band identifies precise location of tip for positioning accuracy

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Flexor® Tuohy-Borst Sidearm Introducers – Ansel Modification

    Used to introduce balloon, closed and nontapered-end catheters or other devices

    • Uniquely fabricated sheath design to provide maximum flexibility without kinking or compression
    • .018 and .038 inch wire compatible dilators included
    • Preformed curves combined with soft distal tip allow atraumatic engagement of target vessels
    • Short dilator tip enhances trackability and facilitates positioning of introducer assembly in tight spaces
    • Radiopaque band, incorporated within sheath material, identifies precise location of sheath’s distal tip for positioning accuracy
    • Use of opened Tuohy-Borst manual-adjusting valve seal permits unimpeded catheter or device introduction.
    • Closed valve position prevents blood reflux, air aspiration and movement of positioned catheter
    • AQ® hydrophilic coating on both sheath and dilator provide an extremely lubricious surface, easing introduction

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Flexor® Tuohy-Borst Sidearm Introducers – Balkin Up & Over® Contralateral Design

    Used for contralateral access to the iliac artery for interventional procedures after initial wire guide positioning gas been established. NOTE: Use of a heavy-duty wire guide is recommended.

    • Uniquely fabricated sheath design provides maximum flexibility without kinking or compression
    • Sheath and dilator configuration facilitates positioning over bifurcation to opposite iliac artery
    • Radiopaque band, incorporated within sheath material, identifies precise location of sheath’s distal tip for positioning accuracy
    • Use of opened Tuohy-Borst manual-adjusting valve seal permits unimpeded catheter or device introduction.
    • Closed valve position prevents blood reflux, air aspiration and movement of positioned catheter.

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Flexor® Tuohy-Borst Sidearm Introducers – Shuttle®-SL

    Used for the introduction of catheters, balloons or other devices

    • Uniquely fabricated sheath design provides maximum flexibility without kinking or compression
    • Radiopaque band, incorporated within the sheath material, identifies precise location of sheath’s distal tip for positioning accuracy
    • Atraumatic soft SL (soft landing) tip design reduces vessel trauma during engagement
    • AQ® hydrophilic coating provides an extremely lubricious surface area for enhanced trackability
    • Tuohy-Borst manual-adjusting valve seal minimises blood loss during device insertion.

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Large Check-Flo® Introducers – Large Valve Assembly

    Used to introduce balloon, closed and nontapered-end catheters and other devices.

    • Radiopaque tip identifies precise location of sheath’s distal tip for positioning accuracy
    • The sidearm fitting allows flushing around the catheter while it is positioned inside the sheath
    • The side-connection line can be used as a second infusion line

    Supplied sterile in peel-open packages. Intended for one-time use

  • Cook® TriForce Peripheral Crossing Set

    Cook® Medical TriForce Peripheral Crossing Set:

    Enhanced penetration

    • The enhanced crossing ability of the CXI® catheter joins with the pushability of the Flexor® sheath to cross vascular lesions.

    Strong pushability

    • A tungsten-loaded tip aids pushability and adds to radiopacity as it goes through the lesion.  The hydrophilic coating on both the CXI and the Flexor sheath enhances trackability.

    Tapered transition

    • The 5 Fr sheath tapers to a 4 Fr catheter that hugs a .035 inch diameter wire guide for an uninterrupted transition.