GI-Endoscopy

  • Cook® Fusion Cytology Brush

    • Intended for the collection of cells in the biliary system
    • The double lumen feature allows wire guide access to the desired duct and facilitates the exchange of wire-guided devices
    • The device is supplied sterile and is disposable – intended for single use only
    Order Number

    Brush Diameter

    Brush Filiform Tip size

    Catheter Fr Size / Length

    Wire Guide* Diameter

    Minimum Accessory Channel

    CK-FS-CB-1.5-S

    3mm

    1.5cm

    8.0/200cm

    .035 inch

    4.2mm

    CK-FS-CB-6

    3mm

    n/a

    6.0/200cm

    .035 inch

    3.2mm

    *Recommended Fusion Wire Guide sold separately.

  • Cook® Fusion Dilation Catheter

    • Used to dilate structures of the biliary tree
    • This device allows easier access with the unique DomeTip technology and provides the catheter stability which is needed to dilate difficult strictures
    • The device is supplied sterile and is disposable – intended for single use only
  • Cook® Fusion ERCP Catheters

    Fusion OMNI ERCP Catheter

    • Used for endoscopic cannulation of the ductal system
    • New DomeTip™ design potentially provides easier access and less trauma during cannulation
    • The device is supplied sterile and is disposable – intended for single use only

    Fusion ERCP Catheter

    • Used for endoscopic cannulation of the ductal system
    • The device is supplied sterile and is disposable – intended for single use only

     

    Order Number

    French Size

    Catheter Length

    Catheter Tip

    Wire Guide Diameter*

    Minimum Accessory Channel

    CK-FS-GT-OMNI

    7.0

    200cm

    Dome

    .035inch*

    4.2mm

    CK-FS-GT-2

    6.0

    200cm

    Dome

    .035inch*

    3.2mm

    *Recommended Fusion Wire Guide sold separately

  • Cook® Fusion Extraction Baskets

    Fusion Extraction Baskets

    • Used for endoscopic removal of biliary stones and foreign bodies
    • The device is supplied sterile and is disposable – intended for single use only
    Order Number

    Basket Diameter / Length

    Catheter Diameter

    Catheter Length

    Wire Guide* Diameter

    Minimum Accessory Channel

    CK-FS-XB-2X4

    2cm x 4cm

    8.0Fr

    200cm

    .035 inch

    4.2mm

    *Recommended Fusion Wire Guide sold separately. NOT to be used with mechanical lithotriptor.

    Fusion Lithotripsy Compatible Extraction Basket

    • Used for endoscopic removal of biliary stones and foreign bodies
    • This basket offers the option of converting to mechanical lithotripsy with no assembly required
    • The device is supplied sterile and is disposable – intended for single use only
    Order Number

    Basket Diameter / Length

    Catheter Diameter

    Catheter Length

    Wire Guide* Diameter

    Minimum Accessory Channel

    CK-FS-LXB-2X4

    2cm x 4cm

    8.0Fr

    208cm

    .035 inch

    4.2mm

    CK-FS-LXB-3X6

    3cm x 6cm

    8.0Fr

    208cm

    .035 inch

    4.2mm

    *Recommended Fusion Wire Guide sold separately. Compatible with Conquest TTC Lithotripsy Cable.

  • Cook® Fusion Needle Knife

    • Intended for accessing the common bile duct when standard cannulation methods have been exhausted
    • The device is supplied sterile and is disposable – intended for single use only
    Order Number

    Catheter French Size/Length

    Catheter Tip

    Cutting Wire Length

    Wire Guide* Diameter

    Minimum Accessory Channel

    CK-FS-PRECUT

    7.0 / 200cm

    6Fr

    4mm Adjustable

    .035inch

    4.2mm

    *Recommended Fusion Wire Guide sold separately

  • Cook® Fusion Quattro™ Extraction Balloon

    • Fusion Quattro Balloon offers four distinct inflation diameters. The triple lumen feature allows for contrast injection and wire guide access to the desired location during extraction
    • Used for endoscopic removal of stones in the biliary system and for contrast injection
    • The device is supplied sterile and is disposable – intended for single use only

    CAUTION: This product contains natural rubber latex, which may cause allergic reactions.

    Order Number

    Balloon Inflated Diameters

    Catheter Diameter / Length

    Injection Port

    Wire Guide* Diameter

    Minimum Accessory Channel

    CK-FS-QEB-A

    8.5, 10, 12, & 15mm

    6.6Fr / 200cm

    Above Balloon

    .035 inch

    3.2mm

    CK-FS-QEB-B

    8.5, 10, 12, & 15mm

    6.6Fr / 200cm

    Below Balloon

    .035 inch

    3.2mm

    CK-FS-QEB-XL-A

    12, 15, 18 & 20mm

    6.6Fr / 200cm

    Above Balloon

    .035 inch

    3.2mm

    CK-FS-QEB-XL-B

    12, 15, 18 & 20mm

    6.6Fr / 200cm

    Below Balloon

    .035 inch

    3.2mm

    *Recommended Fusion Wire Guide sold separately.

  • Cook® Fusion Sphincterotomes

    Fusion OMNI-Tomes

    • Used for cannulation of the ductal system and for sphincterotomy
    • New DomeTip™ design potentially provides easier access and less trauma during cannulation
    • Available preloaded with or without a wire
    • Available in .035 and .021 sizes
    • The device is supplied sterile and is disposable – intended for single use only

    Fusion IDE-TOME

    • Used for cannulation of the ductal system and for sphincterotomy
    • The device is supplied sterile and is disposable – intended for single use only
    Order Number French Size Cutting Wire Length/Type Sphincterotome Tip Wire Guide Diameter* Minimum Accessory Channel
    CK-FS-OMNI 7.0 25mm/ Monofilament Dome .035inch* 3.2mm
    CK-FS-OMNI-35 7.0 25mm/ Monofilament Dome Preloaded with Fusion Wire Guide .035inch 205cm 3.2mm
    CK-FS-25M-35 7.0 25mm/ Monofilament Dome .021inch* 3.2mm
    CK-FS-OMNI-21 5.5 25mm/ Monofilament Dome Preloaded with Tracer® Metro Direct .021inch 480cm 2.8mm
    CK-FS-OMNI-21-480 5.5 25mm/ Monofilament Dome .035inch* 2.8mm

    *Recommended Fusion Wire Guide sold separately. Active cord sold separately.

  • Cook® Fusion Stent Introducers

    Fusion Oasis One Action Stent Introduction System

    • Used for endoscopic biliary stent placement to drain obstructed bile ducts
    • The device is supplied sterile and is disposable – intended for single use only
    • For information on available stent configuration, please refer to the Biliary/Pancreatic section of the Obex website
    Order Number

    Introducer French Size

    Introducer Length

    Radiopaque Band Location

    Wire Guide* Diameter

    Minimum Accessory Channel

    CK-FS-OA-8.5

    8.5

    195cm

    One at IDE port

    .035 inch

    4.2mm

    CK-FS-OA-10

    9.0

    195cm

    One at IDE port

    .035 inch

    4.2mm

    *Recommended Fusion Wire Guide sold separately. Stents sold separately. Not for use with pigtail stents.

    Fusion Pushing Catheter

    • Used for endoscopic biliary stent placement to drain obstructed bile ducts
    • The device is supplied sterile and is disposable – intended for single use only
    • For information on available stent configuration, please refer to the Biliary/Pancreatic section of the Obex website
    Order Number

    Introducer French Size

    Introducer Length

    Wire Guide* Diameter

    Minimum Accessory Channel

    CK-FS-PC-5

    5.0

    170cm

    .035 inch

    3.2mm

    CK-FS-PC-7

    7.0

    170cm

    .035 inch

    3.2mm

    *Recommended Fusion Wire Guide sold separately. Stents sold separately.

  • Cook® Fusion Titan™ Biliary Dilation Balloon

    Cook® Fusion Titan™ Biliary Dilation Balloon

    • Used to dilate structures of the biliary tree
    • This device offers a low profile, minimally compliant balloon for the management of biliary strictures
    • The device is supplied sterile and is disposable – intended for single use only
    Order Number

    Balloon Diameter

    Balloon Length

    Catheter Length

    Wire Guide* Diameter

    Minimum Accessory Channel

    CK-FS-BDB-4X4

    4mm / 12Fr

    4cm

    190cm

    .035 inch

    3.2mm

    CK-FS-BDB-6X4

    6mm / 18Fr

    4cm

    190cm

    .035 inch

    3.2mm

    CK-FS-BDB-8X4

    8mm / 24Fr

    4cm

    190cm

    .035 inch

    3.2mm

    CK-FS-BDB-10X4

    10mm / 30Fr

    4cm

    190cm

    .035 inch

    3.2mm

    *Recommended Fusion Wire Guide sold separately.

  • Cook® Fusion Wire Guide

    • Used to assist in cannulation of the biliary and pancreatic ducts and to aid in bridging difficult strictures during ERCP
    • Placement of the wire allows for continual access to the desired duct and facilitates exchange of compatible wire-guided accessories
    • The device is supplied sterile and is disposable – intended for single use only
    Order Number

    Diameter

    Length

    Tip

    CK-FSW-35

    .035 inch

    205cm

    5cm Aqua coat

  • Cook® Fusion Wire Guide Locking Device

    • Used with endoscopic biliary devices to lock the wire guide(s) in place during ERCP procedures
    • The device is supplied sterile and is disposable – intended for single use only
    • Sold in boxes of 10
    Order Number
    CK-FS-WL-O-10 Olympus Scope Compatible
    CK-FS-WL-P-10 Pentax Scope Compatible

    *Recommended Fusion Wire Guide sold separately

  • Cook® Fusion® Loop Tip™ Wire Guide

    Used to assist in cannulation of the biliary and pancreatic ducts and to aid in bridging difficult strictures during ERCP.
    • Closed distal loop delivers potentially less traumatic access and navigation of the pancreatobiliary ductal system
    • Radiopaque coil spring provides excellent fluoroscopic visibility
    • Spiral markings extending to the distal end of the wire guide provide endoscopic view of wire guide movement during cannulation
    • Nitinol core for kink resistance and shape retention.
    Supplied sterile and is disposable – intended for single use only.
  • Cook® Hemospray™ Endoscopic Hemostat

    This device is used for hemostasis of nonvariceal upper gastrointestinal bleeding.

    Supplied sterile and is disposable – intended single use only.
    • Nonthermal:  No immediate or chronic tissue changes occur as sometimes experienced with thermal modalities
    • Noncontact:  Aerosal delivery system eliminates the need for direct contact at the treatment site
    • Nonspecific targeting:  Powder is sprayed toward the source of the bleed, so it does not require the accuracy needed for conventional modalities
     Order Number
    Reference
    Part Number
    Catheter
    Length
     Catheter Size
    FR
     Minimum Accessory
    Channel
    mm
     G24663  HEMO-7-EU  220  7  2.8
     G21346  HEMO-10-EU 220 10  3.7
  • Cook® Hercules Dilation Balloon

    • Used to dilate strictures of the gastrointestinal tract including strictures of the oesophagus
    • Non wire guided
    • This device is supplied non-sterile and is disposable – intended for single use only
    Order Number

    Balloon Inflated Diameter

    Balloon Length

    Recommended Graduated Pressure

    1>2>3

    Catheter Length

    Minimum Accessory Channel

    CK-HBD-8-9-10

    8-9-10mm

    24-27-30Fr

    8 cm

    60psi / 4atm
    90psi / 6atm
    120psi / 8atm

    180cm

    2.8 mm

    CK-HBD-10-11-12

    10-11-12mm
    30-33-36 Fr

    8cm

    30psi / 2atm
    60psi / 4atm
    90psi / 6atm

    180cm

    2.8 mm

    CK-HBD-12-13.5-15

    12-13.5-15mm
    36-40.5-45 Fr

    8 cm

    30psi / 2atm
    60psi / 4atm
    90psi / 6atm

    180cm

    2.8 mm

    CK-HBD-15-16.5-18

    15-16.5-18mm
    45-49.5-54 Fr

    8 cm

    30psi / 2atm
    60psi / 4atm
    90psi / 6atm

    180cm

    2.8 mm

    CK-HBD-18-19-20

    18-19-20
    54-57-60 Fr

    8 cm

    30psi / 2atm
    60psi / 4atm
    90psi / 6atm

    180cm

    2.8 mm

    *Non-wire guided

  • Cook® Inflation Device

    Used while performing balloon dilation procedures to inflate the balloon, monitor the pressure within the balloon and deflate the balloon.

    • Easy to read luminescent dial
    • Ergonomically shaped 20 cc barrel
    • Quick release lock lever mechanism
    • Maximum pressure of 30 atmospheres
  • Cook® Instinct™ Endoscopic Hemoclip

    This device is used for endoscopic clip placement within the gastrointestinal tract for the purpose of endoscopic marking, hemostasis for mucosal/submucosal defects less than 3cm in the upper GI tract, bleeding ulcers, arteries less than 2mm and polyps less than 1.5cm in diameter in the GI tract lumenal perforations.

     Order
    Number
    Reference 
    Part Number
     Clip Opening
    mm
     Catheter
    Size Fr
     Catheter Length
    cm
    Box
    Quantity
     Accessory
    Channel
    mm
    G18343  INSC-7-230-S 16  7  230  10 2.8
  • Cook® Manometry

    Biliary Manometry Catheter Set

    • Used for motility studies in the common bile duct, pancreatic duct, Sphincter of Oddi and duodenum
    • The device is supplied sterile and is disposable – intended for single use only
    Order NumberCatheter French SizeCatheter LengthCatheter Markings & HolesWire Guide LengthWire Guide* Diameter
    CK-BMCG-15.0200cmTen 1mm Markings & Holes 2mm Apart480cm.018 inch

    *Cope Wire Guide Included

    Lehman Sphincter of Oddi Manometry Catheter

    • Used for motility studies in the common bile duct, pancreatic duct, Sphincter of Oddi and duodenum
    • The device is supplied sterile and is disposable – intended for single use only
    Order NumberCatheter French SizeCatheter LengthCatheter Tip LengthCatheter TipWire Guide* Diameter
    CK-SOM-18-S-LEHMAN-NG5250cmShort – 5mm3.5Fr.018 inch
    CK-SOM-18-L-LEHMAN-NG5250cmLong – 1.5cm3.5Fr.018 inch

    *Recommended Roadrunner wire guide sold separately

  • Cook® Nasal Jejunal Feeding Tube

    • Used to provide short-term enteral access for delivery of nutrition or medications to the small bowel
    • This device is supplied sterile and is disposable – intended for single use only
    Order Number

    Feeding Tube French Size

    Feeding Tube Length

    Wire Guide Diameter

    Wire Guide Length

    CK-NJFT-8

    8.0

    240 cm

    .035 inch

    260 cm

    CK-NJFT-10

    10.9

    240 cm

    .035 inch

    260 cm

    *50 cm nasal transfer tube included

  • Cook® Needle Knives

    Huibregtse® Single Lumen Needle Knife

    • Used for accessing the common bile duct when standard methods of cannulation have been exhausted
    • The PreCurve facilitates tip position
    • The device is supplied sterile and is disposable – intended for single use only
    Order NumberFrench SizeLengthPapillotome Exposed Cutting WireWire Guide* DiameterMinimum Accessory Channel
    CK-HPC-25200cm4mm0.0352.0mm

    *Active cord sold separately

    Huibregtse® Triple Lumen Needle Knife

    • Used for accessing the common bile duct when standard methods of cannulation have been exhausted
    • The PreCurve facilitates tip position
    • The device is supplied sterile and is disposable – intended for single use only
    Order NumberFrench SizeLengthPapillotome Exposed Cutting WireWire Guide* DiameterMinimum Accessory Channel
    CK-HPC-37.0-5.0200cm4mm0.0352.0mm

    *Recommended Tracer Metro Direct Wire Guide sold separately. Active cord sold separately

    Zimmon® Needle Knife Papillotome

    • Used for accessing the common bile duct when standard methods of cannulation have been exhausted
    • Catheter has three etched markings at the distal radiopaque tip
    • The device is supplied sterile and is disposable – intended for single use only
    Order NumberFrench SizeLengthPapillotome Exposed Cutting WireWire Guide* DiameterMinimum Accessory Channel
    CK-PTW-15200cm7mm0.0352.0mm

    *Recommended Tracer Metro Direct Wire Guide sold separately. Active cord sold separately

  • Cook® PEG Jejunal Tubes

    PEG 24® Jejunal

    • Used for percutaneous endoscopic placement to provide enteral nutrition to patients requiring nutritional support
    • Used through a percutaneous endoscopic gastrostomy tube
    • This device is supplied sterile and is disposable – intended for single use only
    Order Number

    Feeding Tube French Size

    Feeding Tube Length

    Wire Guide Diameter

    Wire Guide Length

    CK-PEGJ-12-24

    12.0

    60 cm

    .035 inch

    260 cm

    *Set includes: Standard wire guide, twist lock, air plug and pull tie

    Flow 20® Jejunal

    • Used for percutaneous endoscopic placement to provide enteral nutrition to patients requiring nutritional support
    • Used through a percutaneous endoscopic gastrostomy tube
    • This device is supplied sterile and is disposable – intended for single use only
    Order Number

    Feeding Tube French Size

    Feeding Tube Length

    Wire Guide Diameter

    Wire Guide Length

    CK-FLOWJ-9-20

    9.0

    60 cm

    .028 inch

    260 cm

    *Set includes: Standard wire guide, twist lock, air plug and pull tie

  • Cook® PEG Replacement Devices

    Balloon Replacement Gastrostomy Tube

    • Used for a replacement gastrostomy tube through an established gastrostomy tract
    • This device provides continued access to the stomach for the delivery of nutrition to patients requiring nutritional support
    • This device is supplied sterile and is disposable – intended for single use only
    Order Number

    Balloon Capacity

    Feeding Tube French Size

    CK-PEG-14-BRT

    5 cc

    14.0

    CK-PEG-18-BRT

    20 cc

    18.0

    CK-PEG-24-BRT

    20 cc

    24.0


    Passport® Low Profile Gastrostomy Device

    • Used to replace a gastrostomy tube that has been removed from an established stoma tract
    • This device is supplied sterile and is disposable – intended for single use only
    Order Number

    Feeding Tube French Size

    Feeding Tube Length

    CK-PASS-24-1.2

    24.0

    1.2 cm

    CK-PASS-24-1.7

    24.0

    1.7 cm

    CK-PASS-24-2.4

    24.0

    2.4 cm

    CK-PASS-24-3.4

    24.0

    3.4 cm

    CK-PASS-24-4.4

    24.0

    4.4 cm

    CK-PASS-20-1.2

    20.0

    1.2 cm

    CK-PASS-24-1.7

    20.0

    1.7 cm

    CK-PASS-24-2.4

    20.0

    2.4 cm

    CK-PASS-24-3.4

    20.0

    3.4 cm

    CK-PASS-24-4.4

    20.0

    4.4 cm

  • Cook® PEG Tubes

    PEG 24® Push Method

    • Used for percutaneous endoscopic placement to provide enteral nutrition to patients requiring nutritional support
    • This device is supplied sterile and is disposable – intended for single use only
    Order Number

    Feeding Tube French Size

    Feeding Tube Inner Diameter

    Insertion Wire Diameter

    Insertion Wire Length

    CK-PEG-24-PUSH

    24.0

    5.5 mm

    .035 inch

    240 cm

    Components*
    CK-BFA-24 Bolus Feeding Adaptor
    CK-UFA-24 Universal Feeding Adaptor

    *Components are packaged 5 per box

    PEG 24® Pull Method

    • Used for percutaneous endoscopic placement to provide enteral nutrition to patients requiring nutritional support
    • This device is supplied sterile and is disposable – intended for single use only
    Order Number

    Feeding Tube French Size

    Feeding Tube Inner Diameter

    Insertion Wire Diameter

    Insertion Wire Length

    CK-PEG-24-PULL

    24.0

    5.5 mm

    .035 inch

    150 cm

    Components*
    CK-BFA-24 Bolus Feeding Adaptor
    CK-UFA-24 Universal Feeding Adaptor

    *Components are packaged 5 per box

    Flow 20® Push Method

    • Used for percutaneous endoscopic placement to provide enteral nutrition to patients requiring nutritional support
    • This device is supplied sterile and is disposable – intended for single use only
    Order Number

    Feeding Tube French Size

    Feeding Tube Inner Diameter

    Insertion Wire Diameter

    Insertion Wire Length

    CK-PEG-20-PUSH

    18.61

    4.15 mm

    .035 inch

    240 cm

    Components*
    CK-BFA-18/20 Bolus Feeding Adaptor
    CK-UFA-18/20 Universal Feeding Adaptor

    *Components are packaged 5 per box

    Flow 20® Pull Method

    • Used for percutaneous endoscopic placement to provide enteral nutrition to patients requiring nutritional support
    • This device is supplied sterile and is disposable – intended for single use only
    Order Number

    Feeding Tube French Size

    Feeding Tube Inner Diameter

    Insertion Wire Diameter

    Insertion Wire Length

    CK-PEG-20-PULL

    18.61

    4.15 mm

    .035 inch

    150 cm

    Components*
    CK-BFA-18/20 Bolus Feeding Adaptor
    CK-UFA-18/20 Universal Feeding Adaptor

    *Components are packaged 5 per box

  • Cook® Plastic Biliary Stents and Introducers

    Oasis® One Action Stent Introduction System

    • Used for endoscopic stent placement to drain obstructed biliary ducts
    • The Oasis is compatible with ST-2 Soehendra Tannenbaum®, Cotton-Huibregtse® and Cotton-Leung® stents
    • Available with or without pre-loaded stent
    • The device is supplied sterile and is disposable – intended for single use only
    Order Number

    Pushing Catheter French Size / Length

    Guiding Catheter French Size / Length

    Guiding Catheter Radiopaque Bands

    Wire Guide* Diameter

    Minimum Accessory Channel

    CK-OA-8.5

    8.5 / 170cm

    5.0 / 205cm

    Four Bands at 5cm Apart

    .035 inch

    3.2mm

    CK-OA-10

    10.0 / 170cm

    6.0 / 205cm

    Four Bands at 5cm Apart

    .035 inch

    3.7mm

    CK-OA-11.5

    11.0 / 170cm

    6.0 / 205cm

    Four Bands at 5cm Apart

    .035 inch

    4.2mm

    *Recommended Tracer Metro Direct wire guide sold separately. Not for use with pigtail stents.
    Includes a pushing catheter and guiding catheter.

    Stent Introducer Sets

    • Used for endoscopic stent placement to drain obstructed biliary ducts
    • The device is supplied sterile and is disposable – intended for single use only
    Order Number

    Guiding Catheter French Size

    Guiding Catheter Length

    Pushing Catheter French Size

    Pushing Catheter Length

    Wire Guide* Diameter

    Minimum Accessory Channel

    CK-SIS-8.5

    5.0

    320cm

    8.5

    170cm

    .035 inch

    3.2mm

    CK-SIS-10

    6.0

    320cm

    10.0

    170cm

    .035 inch

    3.2mm

    CK-SIS-11.5

    6.0

    320cm

    11.0

    170cm

    .035 inch

    3.2mm

    *Recommended Tracer Metro Direct wire guide sold separately. Stents sold separately

    Pushing Catheter

    • Used for endoscopic biliary stent placement to drain obstructed bile ducts
    • The device is supplied sterile and is disposable – intended for single use only
    Order Number

    Pushing Catheter French Size

    Pushing Catheter Length

    Wire Guide* Diameter

    Minimum Accessory Channel

    CK-PC-3

    3.0

    170cm

    .018 inch

    2.0mm

    CK-PC-5

    5.0

    170cm

    .035 inch

    2.0mm

    CK-PC-7

    7.0

    170cm

    .035 inch

    2.8mm

    CK-PC-8.5

    8.5

    170cm

    .035 inch

    3.2mm

    CK-PC-10

    10.0

    170cm

    .035 inch

    3.7mm

    CK-PC-11.5

    11.5

    170cm

    .035 inch

    4.2mm

    *Recommended Tracer Metro Direct or Roadrunner wire guide sold separately. Stents sold separately

    Guiding Catheter

    • Used for endoscopic biliary stent placement
    • Introducer components include a wire guide (if applicable), pushing catheter, and guiding catheter (not included with 7 French and smaller stent introducer sets)
    Order Number

    Guiding Catheter French Size

    Guiding Catheter Length

    Compatible Stent** French Size

    Wire Guide* Diameter

    CK-GC-5

    5.0

    320cm

    8.5

    .035 inch

    CK-GC-6

    6.0

    320cm

    10.0 – 11.5

    .035 inch

    *Recommended Tracer Metro Direct wire guide sold separately
    **Stent sold separately

    Soehendra® Stent Retriever

    • Used to cannulate and remove stents from the biliary and pancreatic ducts while maintain wire guide placement
    • The device is supplied sterile and is disposable – intended for single use only
    Order Number

    Retrieved Stent French Size

    Stent Retriever Length

    Wire Guide* Diameter

    Minimum Accessory Channel

    CK-SSR-5

    5.0

    180cm

    .021 inch

    2.8mm

    CK-SSR-7

    7.0

    180cm

    .035 inch

    2.8mm

    CK-SSR-8.5

    8.5

    180cm

    .035 inch

    3.2mm

    CK-SSR-10

    10.0

    180cm

    .035 inch

    3.7mm

    CK-SSR-11.5

    11.5

    180cm

    .035 inch

    4.2mm

    *Recommended Tracer Metro Direct wire guide sold separately
    **Stent sold separately

    Cotton-Leung® (Amsterdam) Biliary Stent Sets or Stent Only

    • Used to drain obstructed biliary ducts
    • Each stent is recommended for use with stent introducer
    • The positioning sleeve included with this set is used to collapse the duodenal flap on the stent to aid introduction into the endoscope channel
    • The device is supplied sterile and is disposable – intended for single use only

    Cotton-Leung® (Amsterdam) Sof-Flex® Biliary Stent Only

    • Used to drain obstructed biliary ducts
    • Made of soft, pliable Sof-Flex radiopaque material for strength and flexibility
    • Each stent is recommended for use with stent introducer
    • The positioning sleeve included with this set is used to collapse the duodenal flap on the stent to aid introduction into the endoscope channel
    • The device is supplied sterile and is disposable – intended for single use only

    ST-2 Soehendra Tannenbaum® Biliary Stent

    • Used to drain obstructed biliary ducts
    • The positioning sleeve included with this stent is used to collapse the duodenal flap on the stent to aid introduction into the endoscope channel
    • The device is supplied sterile and is disposable – intended for single use only
    Order Number

    Stent French Size

    Stent Length*

    CK-TTSO-8.5-5

    8.5

    5cm

    CK-TTSO -8.5-6

    8.5

    6cm

    CK-TTSO -8.5-7

    8.5

    7cm

    CK-TTSO -8.5-8

    8.5

    8cm

    CK-TTSO -8.5-9

    8.5

    9cm

    CK-TTSO -8.5-10

    8.5

    10cm

    CK-TTSO -8.5-11

    8.5

    11cm

    CK-TTSO -8.5-12

    8.5

    12cm

    CK-TTSO -8.5-13

    8.5

    13cm

    CK-TTSO -8.5-14

    8.5

    14cm

    CK-TTSO -8.5-15

    8.5

    15cm

    CK-TTSO -10-5

    10

    5cm

    CK-TTSO -10-6

    10

    6cm

    CK-TTSO -10-7

    10

    7cm

    CK-TTSO -10-8

    10

    8cm

    CK-TTSO -10-9

    10

    9cm

    CK-TTSO -10-10

    10

    10cm

    CK-TTSO -10-11

    10

    11cm

    CK-TTSO -10-12

    10

    12cm

    CK-TTSO -10-13

    10

    13cm

    CK-TTSO -10-14

    10

    14cm

    CK-TTSO -10-15

    10

    15cm

    CK-TTSO -10-15

    10

    15cm

    CK-TTSO -11.5-5

    11.5

    5cm

    CK-TTSO -11.5-6

    11.5

    6cm

    CK-TTSO -11.5-7

    11.5

    7cm

    CK-TTSO -11.5-8

    11.5

    8cm

    CK-TTSO -11.5-9

    11.5

    9cm

    CK-TTSO -11.5-10

    11.5

    10cm

    CK-TTSO -11.5-11

    11.5

    11cm

    CK-TTSO -11.5-12

    11.5

    12cm

    CK-TTSO -11.5-13

    11.5

    13cm

    CK-TTSO -11.5-14

    11.5

    14cm

    CK-TTSO -11.5-15

    11.5

    15cm

    *Length measured between flaps
    **Recommended for use with the Oasis® One Action Stent Introducer System, sold separately

    Solus® Double Pigtail Stent with Introducer

    • Used to drain obstructed biliary ducts
    • Made of soft, pliable Sof-Flex radiopaque material for strength and flexibility
    • Enhanced fluoroscopic visualisation for positioning with two radiopaque bands
    • Each stent is recommended for use with the Solus Stent Introducer System, which includes a pushing catheter and pigtail straightener (if applicable)
    • The device is supplied sterile and is disposable – intended for single use only
    Order Number

    Pushing Catheter

    Size / Length

    Guiding Catheter Size / Length

    Stent French Size

    Stent Length**

    Wire Guide* Diameter

    CK-ZSS-10-1-RB

    10Fr / 165cm

    5Fr / 210cm

    10

    1cm

    .035 inch

    CK-ZSS -10-3-RB

    10Fr / 165cm

    5Fr / 210cm

    10

    3cm

    .035 inch

    CK-ZSS -10-4-RB

    10Fr / 165cm

    5Fr / 210cm

    10

    4cm

    .035 inch

    CK-ZSS-10-5-RB

    10Fr / 165cm

    5Fr / 210cm

    10

    5cm

    .035 inch

    CK-ZSS -10-7-RB

    10Fr / 165cm

    5Fr / 210cm

    10

    7cm

    .035 inch

    CK-ZSS -10-9-RB

    10Fr / 165cm

    5Fr / 210cm

    10

    9cm

    .035 inch

    CK-ZSS-10-10-RB

    10Fr / 165cm

    5Fr / 210cm

    10

    10cm

    .035 inch

    CK-ZSS-10-12-RB

    10Fr / 165cm

    5Fr / 210cm

    10

    12cm

    .035 inch

    CK-ZSS-10-15-RB

    10Fr / 165cm

    5Fr / 210cm

    10

    15cm

    .035 inch

    *Recommended Tracer Metro Direct wire guide sold separately
    **Length measured from base to base of pigtails

    Zimmon® Biliary Stent Sets or Stent Only

    • Used to drain obstructed biliary ducts
    • Each stent is recommended for use with stent introducer components including a pushing catheter
    • The pigtail straightener included with this stent is used to aid the loading of this stent onto the introducer
    • This device is supplied sterile and is disposable – intended for single use only

    Zimmon Biliary Stent Only

    Order Number

    Stent French Size

    Stent Length*

    CK-ZSO-5-4

    5

    4cm

    CK-ZSO -5-7

    5

    7cm

    CK-ZSO -5-10

    5

    10cm

    CK-ZSO-6-4

    6

    4cm

    CK-ZSO -6-7

    6

    7cm

    CK-ZSO -6-10

    6

    10cm

    CK-ZSO-7-4

    7

    4cm

    CK-ZSO -7-7

    7

    7cm

    CK-ZSO -7-10

    7

    10cm

    CK-ZSO-10-4

    10

    4cm

    CK-ZSO -10-7

    10

    7cm

    CK-ZSO -10-10

    10

    10cm

    *Length measured from base to base of pigtails
    **Recommended for use with Stent Introducer Set or Pushing Catheter, sold separately.

    Zimmon Biliary Stent Set

    Order Number

    Stent French Size

    Stent Length**

    Pushing Catheter Length

    Wire Guide* Diameter

    CK-ZEBD-5-4

    5

    4cm

    170cm

    .035 inch

    CK-ZEBD -5-7

    5

    7cm

    170cm

    .035 inch

    CK-ZEBD -5-10

    5

    10cm

    170cm

    .035 inch

    CK-ZEBD -6-4

    6

    4cm

    170cm

    .035 inch

    CK-ZEBD -6-7

    6

    7cm

    170cm

    .035 inch

    CK-ZEBD -6-10

    6

    10cm

    170cm

    .035 inch

    CK-ZEBD -7-4

    7

    4cm

    170cm

    .035 inch

    CK-ZEBD -7-7

    7

    7cm

    170cm

    .035 inch

    CK-ZEBD -7-10

    7

    10cm

    170cm

    .035 inch

    CK-ZEBD -10-4

    10

    4cm

    170cm

    .035 inch

    CK-ZEBD -10-7

    10

    7cm

    170cm

    .035 inch

    CK-ZEBD -10-10

    10

    10cm

    170cm

    .035 inch

    *Recommended Tracer Metro Direct wire guide sold separately
    **Length measured from base to base of pigtails

  • Cook® Plastic Pancreatic Stents and Introducers

    Pushing Catheter

    • Used for endoscopic biliary stent placement to drain obstructed bile ducts
    • The device is supplied sterile and is disposable – intended for single use only

    Zimmon® Pancreatic Stent With or Without Ductal Flaps

    • Used to drain obstructed pancreatic ducts
    • Each stent is recommended for use with stent introducer components including a wire guide and pushing catheter. These components sold separately
    • The device is supplied sterile and is disposable – intended for single use only

    Geenen® Pancreatic Stent Sets or Stent Only

    • Used to drain obstructed biliary ducts
    • Each stent is recommended for use with stent introducer
    • The positioning sleeve included with this set is used to collapse the duodenal flap on the stent to aid introduction into the endoscope accessory channel
    • The device is supplied sterile and is disposable – intended for single use only

    Geenen® Sof-Flex® Pancreatic Stent With or Without Internal Flap

    • Used to drain obstructed pancreatic ducts
    • Made of soft, pliable Sof-Flex radiopaque material for strength and flexibility
    • Each stent is recommended for use with stent introducer
    • The positioning sleeve included with this set is used to collapse the duodenal flap on the stent to aid introduction into the endoscope accessory channel
    • The device is supplied sterile and is disposable – intended for single use only

    Johlin™ Pancreatic Wedge Stent

    • Used to drain obstructed pancreatic ducts
    • The device and introducer are supplied sterile and disposable – intended for single use only