Peripheral Intervention

  • Cook® Advance® 35LP – Low Profile PTA Balloon Dilatation Catheters

    Designed for percutaneous transluminal angioplasty (PTA) of lesions in peripheral arteries including the iliac, renal, popliteal, infrapopliteal, femoral and iliofemoral as well as obstructive lesions of native of synthetic arteriovenous dialysis fistulas.

    Expand procedural options with the first 8mm x 8cm balloon able to pass through a 5 Fr sheath
    Low-profile design tightly tapers to the wire for superior crossing capabilities, while delivering excellent pushability and trackability
    Pliaform™ surface texture and Starcast™ shoulders provide superior balloon rewrap and sheath compatibility
    Double-lumen D-shaped design allows you to rapidly inflate and deflate the balloon, providing quicker restoration of blood flow

  • Cook® Amplatz Extra-Stiff Wire Guides

    Used for interventional cardiovascular and interventional biliary drainage, abscess drainage, uroradiology procedures and catheter exchanges.

    • The increased inner diameter of the wire guide coil allows utilisation of an extra-stiff mandril while maintaining tip flexibility

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Amplatz Stiff Wire Guides

    Used for interventional cardiovascular and interventional biliary drainage, abscess drainage and uroradiology procedures.

    The wire guide has a stiff shaft and a gradual transition to a very flexible distal tip.

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Amplatz Ultra-Stiff Wire Guides

    Used for interventional cardiovascular procedures, interventional biliary drainage, abscess drainage, uroradiology procedures and catheter exchanges.

    The increased inner diameter of the wire guide coil allows utilisation of an ultra-stiff mandril while maintaining tip flexibility.

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Approach® CTO – Microwire Guide

    For use in facilitating delivery of percutaneous catheters into the peripheral vasculature.

    • Supportive stainless steel mandril helps to navigate support catheters smoothly through the vessel
    • Wide selection of tip loads for crossing challenging lesions: 6, 12, 18 and 25 grams
    • Shorter taper provides enhanced pushability and penetration power by focusing the force on the tip
  • Cook® Approach® Hydro ST – Microwire Guide

    For use in facilitating delivery of percutaneous catheters into the peripheral vasculature.

    • Supportive stainless steel shaft helps to navigate support catheters smoothly through the vessel
    • Shorter peripheral-specific taper length, enhanced with hydrophilic coating, is designed for smooth advancement through the vessel
    • Platinum coils in the distal tip give the visibility needed for advancing the wire during challenging cases.
  • Cook® Approach® Pro LT Wire Guide

    Used for facilitating delivery of percutaneous catheters into the peripheral vasculature.

    • Made of linear-elastic nitinol, an alloy that gives high-performance manoeuvrability, support and kink resistance
    • Transmits 1:1 torque response to the distal tip, providing superb directional control and enhanced pushability
    • Palladium-coiled tip provides extra visibility
    • 7cm floppy tip designed for peripheral vascular use

    Available in preformed angled tip or shapeable tip version

  • Cook® Beacon® Tip Royal Flush® Plus High-Flow Catheters – Angiographic Flush

    • Patented enhanced radiopaque Beacon tip provides superior visualisation
    • Gradual transition of radiopaque Beacon tip to catheter shaft results in stability injection
    • Nylon material resists softening during prolonged catheter use
    • Catheter is designed for high-flow, high-pressure contrast media injections
  • Cook® Bentson Wire Guides

    Used for cerebral angiography and other angiographic and interventional procedures.

    • Distal flexibility is helpful in negotiating tortuous and strictured areas of the anatomy
    • Larger diameter core provides additional body for catheter control
    • The distal 6cm of wire guide is extra floppy, providing an atraumatic tip

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Bentson Wire Guides Plus

    Used for cerebral angiography and other angiographic and interventional procedures.

    • Distal flexibility is helpful in negotiating tortuous and strictured areas of the anatomy
    • Larger diameter core provides additional body for catheter control
    • The distal 6cm of wire guide is extra floppy, providing an atraumatic tip

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Bird’s Nest® Gianturco-Roehm Vena Cava Filter

    Proven PE Protection

    • May be used in vena cava up to 40 mm in diameter
    • Controlled insertion for use in varying anatomic conditions while creating a fine wire multiplane filtering system
    • Secure fixation prevents migration
    • Introducer system flexibility permits options in access site selection
  • Cook® Cantata™ Superselective Microcatheter

    Access superselective anatomy with the right balance of trackability, softness and support.

    Ease of access to target anatomy – Hydrophilic coating ensures smooth introduction and maintains manoeuvrability through multiple passes.

    Support and trackability – Five transition zones, more than any other catheter, provide a distinct yet seamless transition from hub to tip.

    Efficient and reliable deployment – Large inner diameter can accommodate embolic particles spheres or microcoils – including .018 inch embolisation coils.

    Additional features:

    • Braided construction for superior control, trackability and kink resistance
    • Lipiodol/DMSO/alcohol compatibility allows a broad range of applications
    • Cantata 2.5 Fr has a flow rate of 1.6mL/sec at a pressure of 1,200 psi
    • Cantata 2.8 Fr has a flow rate of 3.5mL/sec at a pressure of 900 psi