• Cook® Amplatz Extra-Stiff Wire Guides

    Used for interventional cardiovascular and interventional biliary drainage, abscess drainage, uroradiology procedures and catheter exchanges.

    • The increased inner diameter of the wire guide coil allows utilisation of an extra-stiff mandril while maintaining tip flexibility

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Amplatz Stiff Wire Guides

    Used for interventional cardiovascular and interventional biliary drainage, abscess drainage and uroradiology procedures.

    The wire guide has a stiff shaft and a gradual transition to a very flexible distal tip.

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Amplatz Ultra-Stiff Wire Guides

    Used for interventional cardiovascular procedures, interventional biliary drainage, abscess drainage, uroradiology procedures and catheter exchanges.

    The increased inner diameter of the wire guide coil allows utilisation of an ultra-stiff mandril while maintaining tip flexibility.

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Approach® CTO – Microwire Guide

    For use in facilitating delivery of percutaneous catheters into the peripheral vasculature.

    • Supportive stainless steel mandril helps to navigate support catheters smoothly through the vessel
    • Wide selection of tip loads for crossing challenging lesions: 6, 12, 18 and 25 grams
    • Shorter taper provides enhanced pushability and penetration power by focusing the force on the tip
  • Cook® Approach® Hydro ST – Microwire Guide

    For use in facilitating delivery of percutaneous catheters into the peripheral vasculature.

    • Supportive stainless steel shaft helps to navigate support catheters smoothly through the vessel
    • Shorter peripheral-specific taper length, enhanced with hydrophilic coating, is designed for smooth advancement through the vessel
    • Platinum coils in the distal tip give the visibility needed for advancing the wire during challenging cases.
  • Cook® Approach® Pro LT Wire Guide

    Used for facilitating delivery of percutaneous catheters into the peripheral vasculature.

    • Made of linear-elastic nitinol, an alloy that gives high-performance manoeuvrability, support and kink resistance
    • Transmits 1:1 torque response to the distal tip, providing superb directional control and enhanced pushability
    • Palladium-coiled tip provides extra visibility
    • 7cm floppy tip designed for peripheral vascular use

    Available in preformed angled tip or shapeable tip version

  • Cook® Bentson Wire Guides

    Used for cerebral angiography and other angiographic and interventional procedures.

    • Distal flexibility is helpful in negotiating tortuous and strictured areas of the anatomy
    • Larger diameter core provides additional body for catheter control
    • The distal 6cm of wire guide is extra floppy, providing an atraumatic tip

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Bentson Wire Guides Plus

    Used for cerebral angiography and other angiographic and interventional procedures.

    • Distal flexibility is helpful in negotiating tortuous and strictured areas of the anatomy
    • Larger diameter core provides additional body for catheter control
    • The distal 6cm of wire guide is extra floppy, providing an atraumatic tip

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Cope Mandril Wire Guides – Nitinol

    Used for comples diagnostic and interventional procedures.

    • Nitinol mandril is kink resistant and provides 1:1 torque control for increased manoeuvrability within structured areas
    • Platinum coil for increased visualisation and an angled floppy tip for precise directional control
    • Available in standard and short taper lengths

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Disposable Reuter Tip Deflecting Wire Guides

    Used for curving or deflecting catheter tips for pulmonary angiography, selective angiography, translumbar aortography, bronchography, repositioning of central venous catheter tips and other vascular and non-vascular applications.

    • Controlled deflection of the wire guide tip within the catheter lumen and strict imaging control facilitates catheter tip movement.
    • Distal tip of wire guide must never extend beyond distal catheter tip. Intimal damage may occur.
    • The use of a one-size-larger diameter tip deflecting wire guide will prevent wire guide tip from inadvertently exiting catheter tip during manipulation
    • Deflecting wires are 4.0 cm longer than matching catheter so that flush fitting PSFLL-FLL-MLL-90 may be used with assembly.

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Double Flexible Tipped Wire Guides

    Used for access and catheterisation procedures.

    Double flexible tipped design permits alternative use of both ends of wire guide, depending on procedural needs.

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Fixed Core Wire Guides – Straight

    Used for vascular and non-vascular applications.

    Tapered fixed core construction provides gradual transition to a flexible tip.

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Fixed Core Wire Guides Safe-T-J® Curved

    Used for vascular and non-vascular applications.

    “J” configuration of wire guide tip facilitates advancement through tortuous anatomy while minimising inadvertent trauma to the structure.

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Lunderquist-Ring Torque Wire Guides

    Used for non-vascular interventional drainage procedures where a stiff shaft is required with the ability to shape and rotationally control the distal tip.

    TFE-coated wire guides are recommended when using drainage catheters with higher coefficient of friction surface.

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Movable Core Wire Guides – Amplatz Tapered

    Used to negotiate tortuous vessels.

    • Increased inner diameter of wire guide coil and the use of a Tefcor (TFE-coated movable core) produces a low coefficient of friction, allowing ease of advancement and withdrawal of core
    • Tapering of distal end of movable core provides gradual flexible tip transition.

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Movable Core Wire Guides – Coons-Bentson

    Used for vascular and non-vascular applications.

    • Distal flexibility is helpful in negotiating tortuous and strictured areas of the anatomy
    • Tefcor (TFE-coated movable core) provides smooth advancement or withdrawal of the movable core
    • The distal 6cm or wire guide is extra floppy, providing an atraumatic tip

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Newton Wire Guides – LLT – 15cm Tapered Core

    Used for cerebral angiography and other angiographic and interventional procedures.

    Longer tapering of flexible tip is atraumatic and helpful in negotiating tortuous anatomy.

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Newton Wire Guides – LT – 10cm Tapered Core

    Used for cerebral angiography and other angiographic and interventional procedures.

    Longer tapering of flexible tip is atraumatic and helpful in negotiating tortuous anatomy.

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Olcott Torque Device

    Used to facilitate directional control of high torque wire guides.

    • Unique single-handed operation permits rapid position changes during procedural use.
    • Single size allows use with standard and hydrophilic wire guides ranging in size from .014 inch to .045 inch diameter.

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Reuter Tip Deflecting Wire Guides

    Used with Reuter Tip Deflecting Handle for curving or deflecting catheter tips during selective and superselective angiography, pulmonary angiography and other applications.

    • The Reuter Tip Deflecting Handle facilitates catheter tip movement by controlling the deflection of the wire guide tip within the catheter lumen.
    • Distal tip of wire guide must never extend beyond distal catheter tip. Intimal damage may occur.
    • The use of a one size larger diameter tip deflecting wire guide will prevent wire guide tip from inadvertently exiting catheter tip during manipulation.
    • Deflecting wires are 5.5cm longer than matching catheter so that flush fitting PSFLL-FLL-MLL-90 may be used with assembly.

    Supplied sterile in peel-open packages. Intended for one time use.

  • Cook® Roadrunner® Extra Support Wire Guides

    Used for complex diagnostic and interventional procedures where extra support is needed for catheter exchange or manipulation of devices.

    • Heavy-duty nitinol alloy mandril provides support while imparting 1:1 torque response to distal platinum spring coil tip
    • Angled tip facilitates directional control
    • Lubricious TFE coating of mandril portion of wire guide provides low coefficient of friction for smooth manipulations.

    Supplied sterile in peel-open packages. Intended for one time use.

  • Cook® Roadrunner® PC Wire Guides – Nimble®

    Used for complex diagnostic and interventional procedures.

    • Specially tapered super elastic nitinol core transmits 1:1 torque response to the distal tip for enhanced manoeuvrability
    • Nitinol core prevents kinking during manipulation
    • AQ® hydrophilic coating reduces surface friction to facilitate passage through stenosed or strictured anatomy
    • Distal platinum inner spring coil tip provides excellent visualisation during wire guide manipulation
    • The Olcott Torque Device is included to aid directional control of the wire during use.

    Refer to Suggested Instructiosn for Use supplied with product prior to use.

    Supplied sterile in peel-open packages. Intended for one time use.

  • Cook® Roadrunner® PC Wire Guides – Nimble® Floppy

    Used for complex diagnostic and interventional procedures.

    • Specially tapered super-elastic nitinol core transmits 1:1 torque response to the distal tip for enhanced manoeuvrability
    • Nitinol core prevents kinking during manipulation
    • AQ® hydrophilic coating reduces surface friction to facilitate passage through stenosed or strictured anatomy
    • Distal platinum inner spring coil tip provides excellent visualisation during wire guide manipulation
    • The Olcott Torque Device is included to aid directional control of the wire guide during use.

    Refer to suggested Instructions for Use supplied with product prior to use.

    Supplied sterile in peel-open packages. Intended for one time use.

  • Cook® Roadrunner® PC Wire Guides – The Firm™

    Used for complex diagnostic and interventional procedures.

    • Specially tapered super-elastic nitinol core transmits 1:1 torque response to the distal tip for enhanced manoeuvrability
    • Nitinol core prevents kinking during manipulation
    • AQ® hydrophilic coating reduces surface friction to facilitate passage through stenosed or strictured anatomy
    • Distal platinum inner spring coil tip provides excellent visualisation during wire guide manipulation
    • The Olcott Torque Device is included to aid directional control of the wire guide during use.

    Refer to suggested Instructions for Use supplied with product prior to use.

    Supplied sterile in peel-open packages. Intended for one time use.