Peripheral Intervention

  • Cook® Percutaneous Entry Thinwall Needles – Two-Part Cook Modified

    Used for vascular access.

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Percutaneous Entry Thinwall Needles – Winged

    Used for arterial and venous punctures.

    The tapered hub design facilitates wire guide introduction.

    Supplied sterile in peel-open packages. Intended for one-time use.

  • Cook® Polyethylene Catheters – Angiographic

    • Polyethylene material softens during prolonged catheter manipulation
    • Flexible catheter material recommended for low- to medium-pressure applications.
  • Cook® PVA Foam Embolisation Particles

    Used for permanent embolisation of hypervascular lesions and arterio-venous malformations.

    • Differing particle sizes may be chosen for appropriate occlusion of vascular bed abnormalities
    • Transcatheter delivery of PVA is accomplished after closed mixing of particles with contrast media within shipping bottle
    • Sized according to particles passed through graded sieves
    • Only physicians trained and experienced in interventional embolisation and angiographic techniques should use this device.

    Refer to product insert prior to use.

    Supplied in sterile, peel-open packages. Intended for one-time procedural use.

  • Cook® Reuter Tip Deflecting Wire Guides

    Used with Reuter Tip Deflecting Handle for curving or deflecting catheter tips during selective and superselective angiography, pulmonary angiography and other applications.

    • The Reuter Tip Deflecting Handle facilitates catheter tip movement by controlling the deflection of the wire guide tip within the catheter lumen.
    • Distal tip of wire guide must never extend beyond distal catheter tip. Intimal damage may occur.
    • The use of a one size larger diameter tip deflecting wire guide will prevent wire guide tip from inadvertently exiting catheter tip during manipulation.
    • Deflecting wires are 5.5cm longer than matching catheter so that flush fitting PSFLL-FLL-MLL-90 may be used with assembly.

    Supplied sterile in peel-open packages. Intended for one time use.

  • Cook® Roadrunner® Extra Support Wire Guides

    Used for complex diagnostic and interventional procedures where extra support is needed for catheter exchange or manipulation of devices.

    • Heavy-duty nitinol alloy mandril provides support while imparting 1:1 torque response to distal platinum spring coil tip
    • Angled tip facilitates directional control
    • Lubricious TFE coating of mandril portion of wire guide provides low coefficient of friction for smooth manipulations.

    Supplied sterile in peel-open packages. Intended for one time use.

  • Cook® Roadrunner® PC Wire Guides – Nimble®

    Used for complex diagnostic and interventional procedures.

    • Specially tapered super elastic nitinol core transmits 1:1 torque response to the distal tip for enhanced manoeuvrability
    • Nitinol core prevents kinking during manipulation
    • AQ® hydrophilic coating reduces surface friction to facilitate passage through stenosed or strictured anatomy
    • Distal platinum inner spring coil tip provides excellent visualisation during wire guide manipulation
    • The Olcott Torque Device is included to aid directional control of the wire during use.

    Refer to Suggested Instructiosn for Use supplied with product prior to use.

    Supplied sterile in peel-open packages. Intended for one time use.

  • Cook® Roadrunner® PC Wire Guides – Nimble® Floppy

    Used for complex diagnostic and interventional procedures.

    • Specially tapered super-elastic nitinol core transmits 1:1 torque response to the distal tip for enhanced manoeuvrability
    • Nitinol core prevents kinking during manipulation
    • AQ® hydrophilic coating reduces surface friction to facilitate passage through stenosed or strictured anatomy
    • Distal platinum inner spring coil tip provides excellent visualisation during wire guide manipulation
    • The Olcott Torque Device is included to aid directional control of the wire guide during use.

    Refer to suggested Instructions for Use supplied with product prior to use.

    Supplied sterile in peel-open packages. Intended for one time use.

  • Cook® Roadrunner® PC Wire Guides – The Firm™

    Used for complex diagnostic and interventional procedures.

    • Specially tapered super-elastic nitinol core transmits 1:1 torque response to the distal tip for enhanced manoeuvrability
    • Nitinol core prevents kinking during manipulation
    • AQ® hydrophilic coating reduces surface friction to facilitate passage through stenosed or strictured anatomy
    • Distal platinum inner spring coil tip provides excellent visualisation during wire guide manipulation
    • The Olcott Torque Device is included to aid directional control of the wire guide during use.

    Refer to suggested Instructions for Use supplied with product prior to use.

    Supplied sterile in peel-open packages. Intended for one time use.

  • Cook® Rosen Curved Wire Guides

    Used for angioplasty catheter exchange.

    The heavy-duty mandril, 2cm flexible tip and tightened “J” configuration allow atraumatic catheter exchange with minimal extension beyond the catheter tip.

    Supplied sterile in peel-open packages. Intended for one time use.

  • Cook® Rothbarth Uni-Flo™ Infusion Catheters

    Supplied sterile in peel-open packages.  Intended for one-time use.

  • Cook® Royal Flush® II Nylon Catheters – Angiographic Flush

    • High-flow material, kink resistant, low friction coefficient
    • Lower burst point than Royal Flush Plus Nylon