GI-Endoscopy

  • Cook® Quantum TTC® Balloon Dilator

    • Used to dilate strictures of the gastrointestinal tract including strictures of the oesophagus, pylorus, duodenum and colon
    • Non wire guided
    • This device is supplied non-sterile and is disposable – intended for single use only
  • Cook® Quantum TTC® Biliary Balloon Dilator

    • Used to dilate strictures of the Sphincter of Oddi and biliary tree
    • The device is supplied sterile and is disposable – intended for single use only
  • Cook® Quick-Core® Endoscopic Ultrasound Needle

    • Used for soft-tissue biopsy through the accessory channel of an ultrasound endoscope
    • This device is supplied sterile and is disposable – intended for single use only
    Order Number

    Sheath French Size

    Sheath Length

    Adjustable Needle Extension

    Needle Gauge

    Specimen Notch

    Minimum Accessory Channel

    CK-EUSN-19-QC

    5.2

    138 – 140cm

    0-8cm

    19

    20mm

    2.0 mm

  • Cook® Quicksilver® BiPolar Probe

    • Used in conjunction with a single or dual plug bipolar electrosurgical generator to endoscopically provide haemostasis throughout the gastrointestinal tract
    • This device is supplied sterile and is disposable – intended for single use only
    Order Number

    Catheter French Size

    Catheter Length

    Used with Dual Plug Bipolar Generator
    CK-BCP-7A

    7.0

    350 cm

    CK-BCP-10A

    10.0

    350 cm

    Used with Single Plug Bipolar Generator
    CK-BCP-7B

    7.0

    350 cm

    CK-BCP-10B

    10.0

    350 cm

  • Cook® Savary Cleaning Brush

    • Used to clean the lumen of Savary-Gilliard dilators
    • This device is supplied non-sterile and is disposable- intended for single use only
    Order Number

    Cable Length

    Brush Diameter

    CK-SCB-1

    110 cm

    3 mm

  • Cook® Savary-Gilliard® Dilators

    • Used for introducing Savary-Gilliard® dilators
    • This device is supplied non-sterile and is reusable if the device integrity is intact
    • Available individually or as a set

     

  • Cook® Savary-Gilliard® Wire Guide

    • Used for introduce Savary-Gilliard® dilators
    • This device is supplied non-sterile and is reusable if the device integrity is intact
    Order Number

    Length

    CK-SGW-200-SD

    200 cm

    CK-SGW-250-SD

    250 cm

    CK-SGW-360-SD

    360 cm

  • Cook® ShortShot® Saeed Haemorrhoidal Multi-Band Ligators

    Cook® ShortShot® Saeed Haemorrhoidal Multi-Band Ligator with Tri-View Anoscope™

    • Used to ligate internal haemorrhoids, facilitated by an anoscope, for use in adult patients only
    • This device is supplied non-sterile and is disposable – intended for single use only
    Order Number

    Number of Bands

    Outer Diameter

    Length

    CK-HMBL-4-TRI

    4

    15mm

    12.7cm

    *For use with Triview Anoscope

    Cook® ShortShot® Saeed Haemorrhoidal Multi-Band Ligator

    • Used to ligate internal haemorrhoids
    • This device is supplied non-sterile and is disposable – intended for single use only
    Order Number

    Number of Bands

    Outer Diameter

    Length

    CK-HMBL-4

    4

    15mm

    12.7cm

    *Used in conjunction with an anoscope. Anoscope sold separately

  • Cook® Snares

    AcuSnare® One Piece Disposable Snares

    • Used with an electrosurgical unit for endoscopic polypectomy
    • The device is supplied sterile and is disposable – intended for single use only
    Order Number Sheath French Size Snare Size Snare Configuration Minimum Accessory Channel Box Qty
    CK-ASM-1 7.0 1.5cm x 3cm Mini Oval 2.8mm 10
    CK-AS-1 7.0 2.5cm x 5.5cm Standard Oval 2.8mm 10
    CK-ASJ-1 7.0 3cm x 6cm Jumbo Oval 2.8mm 10
    CK-ASMH-1 7.0 1.5cm x 2.5cm Mini Hexagonal 2.8mm 10
    CK-ASH-1 7.0 3cm x 4.5cm Hexagonal 2.8mm 10
    CK-ASDB-15-015 7.0 n/a Duckbill 2.8mm 10
    CK-ASDB-25-015 7.0 n/a Duckbill 2.8mm 10
    CK-AS-1NT 7.0 2.5cm x 5.5cm Standard Oval with Needle Tip 2.8mm 10

    *Active cord available separately

     

    Soft AcuSnare®

    • Used with an electrosurgical unit for endoscopic polypectomy
    • The device is supplied sterile and is disposable – intended for single use only
    Order Number Sheath French Size Snare Size Snare Configuration Minimum Accessory Channel Box Qty
    CK-SASMM-1 7.0 1cm x 1.5cm Micro Mini Oval 2.8mm 10
    CK-SASM-1 7.0 1.5cm x 3cm Mini Oval 2.8mm 10
    CK-SAS-1 7.0 2.5cm x 5.5cm Standard Oval 2.8mm 10
    CK-SASJ-1 7.0 3cm x 6cm Jumbo Oval 2.8mm 10
    CK-SASMH-1 7.0 1.5cm x 2.5cm Mini Hexagonal 2.8mm 10

    *Active cord available separately

     

    Sonnet™ Short Throw Snare

    • The Sonnet Polypectomy Snare is a monopolar electrosurgical device used with an electrical unit for endoscopic polypectomy
    • The device is supplied sterile and is disposable – intended for single use only
    Order Number Sheath French Size Snare Size Snare Configuration Minimum Accessory Channel Box Qty
    CK-SMO-13 7.0 1.5cm x 3cm Mini Oval 2.8mm 10
    CK-SSO-25 7.0 2.5cm x 5.5cm Standard Oval 2.8mm 10
    CK-SJO-29 7.0 3cm x 6cm Jumbo Oval 2.8mm 10
    CK-SSH-28 7.0 3cm x 4.5cm Hexagonal 2.8mm 10
    CK-SASMH-1 7.0 1.5cm x 2.5cm Mini Hexagonal 2.8mm 10

     

    *Active cord available separately

     

  • Cook® Sphincterotomes

    D.A.S.H.® Sphincterotome

    • Used for cannulation of the ductal system and for sphincterotomy. If preloaded, also aids in bridging difficult strictures during ERCP
    • The system allows wire guide access to the desired duct during cannulation and sphincterotomy. Contrast may be injected through an integrated hub
    • The device is supplied sterile and is disposable – intended for single use only
    Order Number

    French Size

    Cutting Wire Length/Type

    Sphincterotome Tip

    Wire Guide Diameter

    Minimum Accessory Channel

    CK-DASH-21-480

    5.5

    25mm/ Monofilament

    Dome

    Preloaded with Tracer® Metro Direct .021inch 480cm

    2.8mm

    CK-DASH-21

    5.5

    25mm/ Monofilament

    Dome

    .021 inch*

    2.8mm

    CK-DASH-21-480

    5.5

    25mm/ Monofilament

    Dome

    Preloaded with Tracer® Metro Direct .021inch 480cm

    2.8mm

    CK-DASH-1

    6.0

    25mm/ Monofilament

    Dome

    .025 inch*

    2.8mm

    CK-DASH-260

    6.0

    25mm/ Monofilament

    Dome

    Preloaded with Tracer® Metro Direct .025inch 260cm

    2.8mm

    CK-DASH-480

    6.0

    25mm/ Monofilament

    Dome

    Preloaded with Tracer® Metro Direct .025inch 480cm

    2.8mm

    CK-DASH-35-480

    7.0

    25mm/ Monofilament

    Dome

    Preloaded with Tracer® Metro Direct .025inch 480cm

    2.8mm

    *Recommended Tracer Metro Direct Wire Guide sold separately. Active cord sold separately

    Tri-Tome pc® Triple Lumen Sphincterotome

    • Used for cannulation of the ductal system and for sphincterotomy
    • Pre-curved radiopaque tip provides optimal cutting orientation. The triple lumen feature allows wire guide access during sphincterotomy and allows contrast injection through a separate lumen
    • The device is supplied sterile and is disposable – intended for single use only
    Order Number

    French Size

    Cutting Wire Length/Type

    Sphincterotome Tip

    Wire Guide Diameter

    Minimum Accessory Channel

    CK-TRI-20

    6.0

    20mm/ Braided

    Dome

    .035*

    2.8mm

    CK-TRI-20M

    6.0

    20mm/ Monofilament

    Dome

    .035*

    2.8mm

    CK-TRI-25

    6.0

    25mm/ Braided

    Dome

    .035*

    2.8mm

    CK-TRI-25M

    6.0

    25mm/ Monofilament

    Dome

    .035*

    2.8mm

    CK-TRI-25-SLT

    6.0

    25mm/ Monofilament

    Dome

    .035*

    2.8mm

    CK-TRI-25M-MET

    6.0

    25mm/ Monofilament

    Dome

    Preloaded with Tracer® Metro Direct .035inch 480cm

    2.8mm

    CK-TRI-30

    6.0

    30mm/ Braided

    Dome

    .035*

    2.8mm

    TRI-30M

    6.0

    30mm/ Monofilament

    Dome

    .035*

    2.8mm

    *Recommended Tracer Metro Direct Wire Guide sold separately. Active cord sold separately

    Cotton Cannulatome® II PreCurved Double Lumen Sphincterotome

    • Used for cannulation of the ductal system and sphincterotomy
    • Pre-curved radiopaque tip provides optimal cutting orientation. The double lumen feature allows injection of contrast or wire guide access
    • The device is supplied sterile and is disposable – intended for single use only
    Order Number

    French Size

    Cutting Wire Length/Type

    Sphincterotome Tip

    Wire Guide* Diameter

    Minimum Accessory Channel

    CK-CT-20

    6.0

    20mm/ Braided

    Dome

    .035

    2.8mm

    CK-CT-20M

    6.0

    20mm/ Monofilament

    Dome

    .035

    2.8mm

    CK-CT-30

    6.0

    30mm/ Braided

    Dome

    .035

    2.8mm

    CK-CT-30M

    6.0

    30mm/ Monofilament

    Dome

    .035

    2.8mm

    *Recommended Tracer Metro Direct Wire Guide sold separately. Active cord sold separately

    MiniTome® PreCurved Double Lumen Sphincterotome

    • Used for cannulation of the ductal system and for sphincterotomy
    • Pre-curved radiopaque tip provides optimal cutting orientation
    • The double lumen feature allows wire guide access during sphincterotomy and facilitates the exchange of wire guided devices
    • Accepts an .021 wire guide
    • The device is supplied sterile and is disposable – intended for single use only
    Order Number

    French Size

    Cutting Wire Length

    Cutting Wire Type

    Wire Guide Diameter

    Minimum Accessory Channel

    CK-MT-20

    5.0-4.0

    20mm

    Braided

    .021*

    2.0mm

    CK-MT-20M

    5.0-4.0

    20mm

    Monofilament

    .021*

    2.0mm

    CK-MT-25

    5.0-4.0

    25mm

    Braided

    .021*

    2.0mm

    CK-MT-25M

    5.0-4.0

    25mm

    Monofilament

    .021*

    2.0mm

    CK-MT-30

    5.0-4.0

    30mm

    Braided

    .021*

    2.0mm

    CK-MT-30M

    5.0-4.0

    30mm

    Monofilament

    .021*

    2.0mm

    *Recommended Tracer Metro Direct Wire Guide sold separately. Active cord sold separately

    Billroth II Sphincterotome

    • Used for cannulation of the ductal system and for sphincterotomy
    • This device is available in double lumen, allowing injection of contrast or wire guide access to the desired duct during sphincterotomy and facilitating the exchange of wire guided devices
    • The device is supplied sterile and is disposable – intended for single use only
    Order Number

    French Size

    Cutting Wire Length

    Cutting Wire Type

    Wire Guide Diameter

    Minimum Accessory Channel

    CK-PTG-20-6BII-NG

    6.0-5.0

    20mm

    Braided

    .035*

    2.8mm

    *Recommended Tracer Metro Direct Wire Guide sold separately. Active cord sold separately

    Soehendra® BII Sphincterotome

    • Used for cannulation of the ductal system and for sphincterotomy
    • Pre-curved radiopaque tip provides optimal cutting orientation
    • The device is supplied sterile and is disposable – intended for single use only
    Order Number

    French Size

    Exposed Cutting Wire

    Length

    Wire Guide Diameter

    Minimum Accessory Channel

    CK-PT-5.5-BII-SOEHENDRA

    5.5

    Variable

    200cm

    .035*

    2.8mm

    *Recommended Tracer Metro Direct Wire Guide sold separately. Active cord sold separately

    UTS® PreCurved Ultra Taper Sphincterotome

    • PreCurved radiopaque tip provides optimal cutting orientation
    • The double lumen feature allows injection of contrast or wire guide access during sphincterotomy and facilitates the exchange of wire guided devices
    • The device is supplied sterile and is disposable – intended for single use only
    Order Number

    French Size

    Cutting Wire Length

    Cutting Wire Type

    Wire Guide Diameter

    Minimum Accessory Channel

    CK-UTS-15

    5.0-4.0

    15mm

    Braided

    .021*

    2.0mm

    CK-UTS-20

    5.0-4.0

    20mm

    Braided

    .021*

    2.0mm

    CK-UTS-20M

    5.0-4.0

    20mm

    Monofilament

    .021*

    2.0mm

    CK-UTS-25

    5.0-4.0

    25mm

    Braided

    .021*

    2.0mm

    CK-UTS-25M

    5.0-4.0

    15mm

    Monofilament

    .021*

    2.0mm

    CK-UTS-30

    5.0-4.0

    30mm

    Braided

    .021*

    2.0mm

    CK-UTS-30M

    5.0-4.0

    30mm

    Monofilament

    .021*

    2.0mm

    *Recommended Tracer Metro Direct Wire Guide sold separately. Active cord sold separately

  • Cook® Transluminal Biliary Biopsy Forceps Set

    Achieve percutaneous biliary access and perform transluminal forceps biopsy with one efficient set. Obtain a comprehensive and convenient array of set components that feature the following technologies:  EchoTip® needles for visibility, the Aprima™ Access set for smooth entry into the biliary tree, and biopsy forceps that are ideally suited for sampling.

  • GI Supply ScopeTote™ Transportation Bag

    ScopeTote™ is ideal for transporting contaminated medical equipment. This clear 24” by 20” reclosable bag easily holds all types of endoscopes as well as other types of soiled medical equipment – neatly, cleanly and compactly.