Cardiothoracic Surgery

  • Genesee Intra-Art® Coronary Artery Occluder

    • Prevent haemorrhage in patients with collateral coronary circulation or when warm cardioplegia is used
    • Improves exposure of the coronary artery during anastomosis
    • Bullet shape tips for gentle but firm insertion
    • Variable separation of occluder tips enhances versatility
    • Monofilaments resist needle damage
    • Available in four sizes: 1.5mm, 2.0mm, 2.5mm and 3.0mm
  • Genesee LocNess® Tissue Stabilisation System

    The LocNess re-usable articulating arm offers substantial savings versus single use disposable devices by greatly reducing cost per procedure.

    Versatile System:

    • Multi-functional knob locks arm into rigid position and holds epicardial stabiliser feet in a firm lock-tight position
    • Stabiliser is designed to be used with a variety of attachments for on and off pump procedures and valve surgery
    • Universal mount allows LocNess to be attached to any sternal retractor
  • Genesee MINIMAX Minimally Invasive Adult Retractor

    MINIMAX Adult Retractor with Interchangeable Blades

    Multipurpose Retractor for Minimally Invasive Approaches
    Streamlined design:
    • Hinged arms equalise pressure points across the incision
    • Changeable blades allow adjustment for individual patient anatomy
    Minimally Invasive Approaches:
    • Deep or standard minimally invasive blade options
    • Optimal standard for TAVR procedures
  • Genesee Myocardial Needle Temperature Probes

    Myocardial Temperature Probes and Adapter Cables

    • Small needle diameter (22 gauge) allows for easy insertion
    • Available in 2100 and popular Y.S.I. 400 series
    • Needles available in 15mm, 30mm and 44mm
    • 6 ft. lead wire allows connection to be away from the patient, table and sterile field.
  • Genesee Neonate Sternal Retractor

    Multipurpose retractors for valve or cardiac repair and the correction of congenital cardiac abnormalities

    Innovative Design:

    • Curved rack with hinged arms allow retractor to hug patient’s body unobtrusively
    • Unique ball clamps and pillar clamp provide fast set-up and unlimited versatility in tissue retraction
    • Pivoting retractor blades align with the edges of the sternum, applying pressure evenly across the sternum

    Versatility of Exposure:

    • Interchangeabe rakes combined with ball clamps
    • Unique shapes of ball and pillar clamps prevent suture sagging
    • Suitable for patients weighting 0.5 kg to 5 kg
    • Includes sterilisation tray
  • Genesee Paediatric Quadretractor®

    Unique multi-use retractor for minimally invasive procedures.

    • Minimal skin incisions
    • Attachable tissue retractors
    • Ideal for muscle sparing procedures
    • Interchangeable sizes of blades/racks
    • Adjustable and lockable platform for different patient anatomies
    • Suitable for patients up to 13 kg
    • Includes sterilisation tray
  • Genesee Paediatric Sternal Retractor

    Multipurpose retractors for valve or cardiac repair and the correction of congenital cardiac abnormalities.

    Innovative Design:

    • Curved rack with hinged arms allow retractor to hug patient’s body unobtrusively
    • Unique ball clamps, Rotary H Bar and pillar clamp allow fast set-up and unlimited versatility in tissue retraction
    • Pivoting retractor blades align with the edges of the sternum, applying pressure evenly across the sternum
    • Simple latch system allows surgeon to adjust pivoting blades to patient size (not available on Neonate Retractor)

    Versatility of Exposure:

    • Interchangeable rakes combined with ball clamps and H Bar produce excellent exposure of mitral, aortic and tricuspid valves
    • Unique shapes of ball and pillar clamps prevent suture sagging
    • Suitable for patients weighing 2 kg to 15 kg
    • Includes sterilisation tray
  • Genesee Premature, Neonate and Paediatric Hinged Sternal Retractor

    • The Genesee Premature, Neonate and Paediatric Hinged Retractors are a unique, high quality instruments for use on premature infants for congenital repairs.
    • The attached hinged blades allow the rack to rotate from the abdomen to the neck, providing unrestricted exposure.
    • Low profile provides excellent visualisation.
  • Genesee Reusable LocNess® Rakes

     

    • Small Atrial and Aortic Rake
    • Medium Atrial and Aortic Rake
    • Large Left Atrial Aortic Rake
    • Wide Atrial and Aortic Rake
    • Long Atrial and Aortic Rake
  • Genesee Shaw Shod™ Suture Guards

    Bridged to Protect

    Unique guard designed to protect and prevent sutures from catching in clamps or scissors.

    Patented design – unique bridge spans boots to prevent suture entanglement

    • Radiopaque
    • Latex-Free

    Quick and Easy to Load

    • No need to line up suture before use
  • Genesee Tenderfoot® Epicardial Suction Cup Stabiliser Feet

    • Small, vertical right mount, non-occlusive
    • Small, vertical left mount, non-occlusive
    • Medium, vertical right mount, non-occlusive
    • Medium, vertical left mount, non-occlusive
  • MedXpert Pectus Excavatum System (P.E.S.)

    As an innovative evolution of former surgical treatment standards for pectus excavatum – mostly invasive procedures with relatively high blood loss, long operation and rehabilitation time and quite often unsatisfactory long-term cosmetic results – the minimally invasive repair (P.E.S.) has the following benefits:

    • Minimally invasive vs. “open” technique with less complications
    • Small and cosmetically unobtrusive incisions
    • Minimal blood loss (<30ml vs. >300ml)
    • Significantly reduced operating time (<60 minutes)
    • Short hospitalisation
    • Quick rehabilitation and return to regular activities
    • Excellent long-term results